Pacific AD200-E Acoustic Door Set STC/Rw 40
The AD200-E Exterior is a tested acoustic door set designed to reduce sound transmission between buildings and outdoor situations.
The AD200-E Exterior is a hinged flush panel door that is suitable for sheltered exterior use. It is available as a single or paired door set.
The thickness of the AD200-E door leaf is 51mm with an approximate leaf weight of 35kg/m2
Wall Type | Acoustic Rating | Door Application | Max Leaf Height (mm) |
Max Leaf Width (mm) |
Steel Stud Wall Timber Stud Wall Masonry Wall |
STC/Rw 40 | Single | 2700 | 1200 |
Pair | 2700 | 1200 |
Notes:
- Please note that the maximum leaf width shown above is measured per door leaf.
Seals
The perimeter frame seals are self-adhesive seals mounted in the frame rebate, so are hidden when the door is closed.
The bottom seal (Type T) is an aluminium threshold (natural anodised) with integral seal.
The height of the gap between the finished floor level and the bottom of the door must be set up carefully during installation of the door set so that the door will engage with the threshold seal as intended.
Hardware
The AD200-E requires suitable latching in order for the frame seals to fully seal the gap between door leaf and frame.
Practically any standard door hardware can be used on the AD200-E, however the proposed hardware must be advised to Pacific Door Systems Ltd to assess the suitability, before manufacture.
Any penetrations through the leaf should be packed with acoustic materials (e.g. batts) wherever possible.
Concealed hinges are not an option on this doorset.
Recommended latching points are shown in the below diagram. Pair doorsets require a designated inactive leaf which is secured top and bottom.
Product Options
Leaf Facings
The facings listed below are available for the AD200 door set
- Metal Sheet, Galv or stainless (0.9mm)*
Notes:
- Of the above facings only those marked * may extend around the door edge.
- Other facings may be available, please contact Pacific Doors to discuss further options.
Leaf Edges
The leaf edges listed below are available for the AD200 door set
Frame Types & Profiles
Timber Frame
Timber frames are not available for the AD200-E.
Steel Frame
The steel frame profiles listed below are available for the AD200 door set
Steel frames require packing of the frame during installation with fibrous insulation material (e.g. fibreglass, mineral wool or polyester batts).
For more in depth information on frame profiles and sizes, please see our Installation Instructions.
Meeting Stiles
The meeting stiles listed below are applicable to pair door sets only.
Wall Types
Door sets must be installed carefully with particular attention to the sealing of gaps, including around the frame to wall junction.
Smoke control
AD-series acoustic doors are available with a smoke control rating (-/-/-/ SM). These doors comply with the NZBC C/AS2 C6.1.2 definition of smoke control doors.
Product Optional Extras
Vision Panels
The AD200-E exterior door set does not include vision panels.
Sidelights and Overlights
Sidelights and ovelights are not an option on this door set as it would impact the acoustic performance of the door set.
Overpanels
Overpanels are not an option on this door set as it would impact the acoustic performance of the door set.
Additional Door Options
Push or Kickplates
Kickplates of any kind can be surface mounted to this door set.
Acoustical Performance Graphs
Acoustical performance graphs
Thermal Insulation
This door leaf has a thermal insulation rating (R-value) of 0.811 Km2/W.