Installation Instructions

 

This tool is designed to filter the available results as you search. Once you have applied a filter, you may need to reset the filter to be able to see all other available options.

 

Please note:  Hardware is not included with our doors. However, we are pleased to help in sourcing high-quality hardware from ASSA ABLOY at an additional cost.

For BPIR Documents related to ASSA ABLOY hardware, please see: ASSA ABLOY 

For hardware from other suppliers, please refer to the individual hardware supplier for information.

 

To see our installation videos please click here.

Installation wall framing requirements

Pacific AD100 Acoustic Door Set STC/Rw 35

WALL TYPE: Timber stud
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Fasteners:

  • Frame - Either nailed (75 x 3.2mm) or screwed (10g x 75mm) at 600mm centres nominal. Two fixings per location.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.
  • Pryda Jamb-fixa brackets Type JFB100 at 500mm centres may be used.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-T-T1 image
WALL TYPE: Timber stud
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Recommended Fasteners:

  • Frame - Either nailed (75 x 3.2mm) or screwed (10g x 75mm) at 600mm centres nominal. Two fixings per location.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.
  • Pryda Jamb-fixa brackets Type JFB100 at 500mm centres may be used.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-T-T2 image
WALL TYPE: Timber stud
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Recommended Fasteners:

  • Frame - Either nailed (75 x 3.2mm) or screwed (10g x 75mm) at 600mm centres nominal. Two fixings per location.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.
  • Pryda Jamb-fixa brackets Type JFB100 at 500mm centres may be used.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-T-T3 image
WALL TYPE: Timber stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Folded steel connection plates (as shown) to be supplied with frames.
  • Hook onto frame bracing straps and nail or screw to timber studs.
  • Frame connection plates either clouts (30 x 2.5mm gib clouts) or screw fixed.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - single central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • Not applicable
A-D-AD-S-T1 image
WALL TYPE: Timber stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Framing stud No.1 screwed to jamb.
  • Connection to stud No.2 via rebated nail on plates. One fastener per location except at bottom where two fasteners are required.
  • Frame to be screw fixed (10g x 50mm self tapping) at 600mm nominal centres. Two fasteners per location where applicable.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • Not applicable
A-D-AD-S-T2 image
WALL TYPE: Timber stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frame screwed to stud through packing between stud and shims.
  • Frame to be screw fixed (10g x 50mm self tapping) at 600mm nominal centres. Two fasteners per location where applicable.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-S-T3 image
WALL TYPE: Timber stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frames may be screwed directly to studs either through the stud and into the frame bracing straps or through the frame into the timber stud at 600mm centres nominal.
  • Frame to be screw fixed (10g x 50mm self tapping) at 600mm centres nominal. Two fasteners per location where applicable.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • Not applicable
A-D-AD-S-T4 image
WALL TYPE: Timber stud
FRAME TYPE: Steel, 2-part
A-D-2 Part-S-T1 image
WALL TYPE: Masonry
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Fasteners:

  • Frame - M8 or M10 'Ramset' Dynabolts at 600mm centres nominal and near hinges. Fixings on or near centre of frame jamb.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - single central fastener required

Wedging gap:

  • 0-10mm
A-D-AD-T-M image
WALL TYPE: Masonry
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Jamb fixing at 600mm centres minimum
  • Expansion anchors eg. M10 countersunk 'Ramset' Dynabolts
  • M12 countersunk masonry screwbolts

Head Fixing (minimum):

  • Single door - none required
  • Paired door - single central fastener required

Wedging Gap:

  • 0-10mm
A-D-AD-S-M image
WALL TYPE: Steel stud
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Fasteners:

  • Frame - Screwed (10g x 50mm self tapping) at 600mm centres nominal. Minimum of one screw per location.
  • Frames may also be installed by screw fixing the steel studs to the back of the timber frame during wall construction.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-T-S1 image
WALL TYPE: Steel stud
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Recommended Fasteners:

  • Frame - Screwed (10g x 50mm self tapping) at 600mm centres nominal and near hinges. Two screws per location
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-T-S2 image
WALL TYPE: Steel stud
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Recommended Fasteners:

  • Frame - Screwed (10g x 50mm self tapping) at 600mm centres nominal. Minimum of one screw per location. Frames may also be installed by screw fixing the steel studs to the back of the timber frame during wall construction.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-T-S3 image
WALL TYPE: Steel stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frame screwed to boxed stud at 600mm centres nominal with self tapping screws.
  • Steel studs may be riveted (steel pop rivets) or screwed (9g x 45mm self tapping) to the frame bracing straps at 600mm centres nominal.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • Not applicable
A-D-AD-S-S1 image
WALL TYPE: Steel stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frame screwed to boxed stud at 600mm centres nominal with self tapping screws.
  • Steel studs may be riveted (steel pop rivets) or screwed (9g x 45mm self tapping) to the frame bracing straps at 600mm centres nominal.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • Not applicable
A-D-AD-S-S2 image
WALL TYPE: Steel stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frame screwed to boxed studs with packing steel shims at 600mm centres nominal.
  • Steel studs may be riveted (steel pop rivets) or screwed (9g x 45mm self tapping) to the frame bracing straps at 600mm centres nominal.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging Gap:

  • 0-10mm
A-D-AD-S-S3 image
WALL TYPE: Steel stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frame screwed to boxed studs with packing steel shims at 600mm centres nominal.
  • Steel studs to be screwed (9g x 75mm self tapping) to the frame bracing straps at 600mm centres nominal.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging Gap:

  • 0-10mm
A-D-AD-S-S4 image
WALL TYPE: Steel stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frame screwed to boxed studs with packing steel shims at 600mm centres nominal.
  • Steel studs to be screwed (14g x 125mm self tapping) to the frame bracing straps at 600mm centres nominal.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging Gap:

  • 0-10mm
A-D-AD-S-S5 image

Pacific AD200-I Acoustic Door Set STC/Rw 38

WALL TYPE: Timber stud
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Fasteners:

  • Frame - Either nailed (75 x 3.2mm) or screwed (10g x 75mm) at 600mm centres nominal. Two fixings per location.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.
  • Pryda Jamb-fixa brackets Type JFB100 at 500mm centres may be used.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-T-T1 image
WALL TYPE: Timber stud
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Recommended Fasteners:

  • Frame - Either nailed (75 x 3.2mm) or screwed (10g x 75mm) at 600mm centres nominal. Two fixings per location.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.
  • Pryda Jamb-fixa brackets Type JFB100 at 500mm centres may be used.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-T-T2 image
WALL TYPE: Timber stud
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Recommended Fasteners:

  • Frame - Either nailed (75 x 3.2mm) or screwed (10g x 75mm) at 600mm centres nominal. Two fixings per location.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.
  • Pryda Jamb-fixa brackets Type JFB100 at 500mm centres may be used.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-T-T3 image
WALL TYPE: Timber stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Folded steel connection plates (as shown) to be supplied with frames.
  • Hook onto frame bracing straps and nail or screw to timber studs.
  • Frame connection plates either clouts (30 x 2.5mm gib clouts) or screw fixed.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - single central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • Not applicable
A-D-AD-S-T1 image
WALL TYPE: Timber stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Framing stud No.1 screwed to jamb.
  • Connection to stud No.2 via rebated nail on plates. One fastener per location except at bottom where two fasteners are required.
  • Frame to be screw fixed (10g x 50mm self tapping) at 600mm nominal centres. Two fasteners per location where applicable.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • Not applicable
A-D-AD-S-T2 image
WALL TYPE: Timber stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frame screwed to stud through packing between stud and shims.
  • Frame to be screw fixed (10g x 50mm self tapping) at 600mm nominal centres. Two fasteners per location where applicable.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-S-T3 image
WALL TYPE: Timber stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frames may be screwed directly to studs either through the stud and into the frame bracing straps or through the frame into the timber stud at 600mm centres nominal.
  • Frame to be screw fixed (10g x 50mm self tapping) at 600mm centres nominal. Two fasteners per location where applicable.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • Not applicable
A-D-AD-S-T4 image
WALL TYPE: Timber stud
FRAME TYPE: Steel, 2-part
A-D-2 Part-S-T1 image
WALL TYPE: Masonry
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Fasteners:

  • Frame - M8 or M10 'Ramset' Dynabolts at 600mm centres nominal and near hinges. Fixings on or near centre of frame jamb.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - single central fastener required

Wedging gap:

  • 0-10mm
A-D-AD-T-M image
WALL TYPE: Masonry
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Jamb fixing at 600mm centres minimum
  • Expansion anchors eg. M10 countersunk 'Ramset' Dynabolts
  • M12 countersunk masonry screwbolts

Head Fixing (minimum):

  • Single door - none required
  • Paired door - single central fastener required

Wedging Gap:

  • 0-10mm
A-D-AD-S-M image
WALL TYPE: Steel stud
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Fasteners:

  • Frame - Screwed (10g x 50mm self tapping) at 600mm centres nominal. Minimum of one screw per location.
  • Frames may also be installed by screw fixing the steel studs to the back of the timber frame during wall construction.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-T-S1 image
WALL TYPE: Steel stud
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Recommended Fasteners:

  • Frame - Screwed (10g x 50mm self tapping) at 600mm centres nominal and near hinges. Two screws per location
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-T-S2 image
WALL TYPE: Steel stud
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Recommended Fasteners:

  • Frame - Screwed (10g x 50mm self tapping) at 600mm centres nominal. Minimum of one screw per location. Frames may also be installed by screw fixing the steel studs to the back of the timber frame during wall construction.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-T-S3 image
WALL TYPE: Steel stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frame screwed to boxed stud at 600mm centres nominal with self tapping screws.
  • Steel studs may be riveted (steel pop rivets) or screwed (9g x 45mm self tapping) to the frame bracing straps at 600mm centres nominal.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • Not applicable
A-D-AD-S-S1 image
WALL TYPE: Steel stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frame screwed to boxed stud at 600mm centres nominal with self tapping screws.
  • Steel studs may be riveted (steel pop rivets) or screwed (9g x 45mm self tapping) to the frame bracing straps at 600mm centres nominal.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • Not applicable
A-D-AD-S-S2 image
WALL TYPE: Steel stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frame screwed to boxed studs with packing steel shims at 600mm centres nominal.
  • Steel studs may be riveted (steel pop rivets) or screwed (9g x 45mm self tapping) to the frame bracing straps at 600mm centres nominal.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging Gap:

  • 0-10mm
A-D-AD-S-S3 image
WALL TYPE: Steel stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frame screwed to boxed studs with packing steel shims at 600mm centres nominal.
  • Steel studs to be screwed (9g x 75mm self tapping) to the frame bracing straps at 600mm centres nominal.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging Gap:

  • 0-10mm
A-D-AD-S-S4 image
WALL TYPE: Steel stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frame screwed to boxed studs with packing steel shims at 600mm centres nominal.
  • Steel studs to be screwed (14g x 125mm self tapping) to the frame bracing straps at 600mm centres nominal.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging Gap:

  • 0-10mm
A-D-AD-S-S5 image

Pacific AD200-E Acoustic Door Set STC/Rw 40

WALL TYPE: Timber stud
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Fasteners:

  • Frame - Either nailed (75 x 3.2mm) or screwed (10g x 75mm) at 600mm centres nominal. Two fixings per location.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.
  • Pryda Jamb-fixa brackets Type JFB100 at 500mm centres may be used.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-T-T1 image
WALL TYPE: Timber stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Folded steel connection plates (as shown) to be supplied with frames.
  • Hook onto frame bracing straps and nail or screw to timber studs.
  • Frame connection plates either clouts (30 x 2.5mm gib clouts) or screw fixed.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - single central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • Not applicable
A-D-AD-S-T1 image
WALL TYPE: Masonry
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Fasteners:

  • Frame - M8 or M10 'Ramset' Dynabolts at 600mm centres nominal and near hinges. Fixings on or near centre of frame jamb.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - single central fastener required

Wedging gap:

  • 0-10mm
A-D-AD-T-M image
WALL TYPE: Masonry
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Jamb fixing at 600mm centres minimum
  • Expansion anchors eg. M10 countersunk 'Ramset' Dynabolts
  • M12 countersunk masonry screwbolts

Head Fixing (minimum):

  • Single door - none required
  • Paired door - single central fastener required

Wedging Gap:

  • 0-10mm
A-D-AD-S-M image
WALL TYPE: Steel stud
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Fasteners:

  • Frame - Screwed (10g x 50mm self tapping) at 600mm centres nominal. Minimum of one screw per location.
  • Frames may also be installed by screw fixing the steel studs to the back of the timber frame during wall construction.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-T-S1 image
WALL TYPE: Steel stud
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Recommended Fasteners:

  • Frame - Screwed (10g x 50mm self tapping) at 600mm centres nominal. Minimum of one screw per location. Frames may also be installed by screw fixing the steel studs to the back of the timber frame during wall construction.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-T-S3 image
WALL TYPE: Steel stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frame screwed to boxed stud at 600mm centres nominal with self tapping screws.
  • Steel studs may be riveted (steel pop rivets) or screwed (9g x 45mm self tapping) to the frame bracing straps at 600mm centres nominal.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • Not applicable
A-D-AD-S-S1 image
WALL TYPE: Steel stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frame screwed to boxed stud at 600mm centres nominal with self tapping screws.
  • Steel studs may be riveted (steel pop rivets) or screwed (9g x 45mm self tapping) to the frame bracing straps at 600mm centres nominal.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • Not applicable
A-D-AD-S-S2 image
WALL TYPE: Steel stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frame screwed to boxed studs with packing steel shims at 600mm centres nominal.
  • Steel studs may be riveted (steel pop rivets) or screwed (9g x 45mm self tapping) to the frame bracing straps at 600mm centres nominal.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging Gap:

  • 0-10mm
A-D-AD-S-S3 image
WALL TYPE: Steel stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frame screwed to boxed studs with packing steel shims at 600mm centres nominal.
  • Steel studs to be screwed (9g x 75mm self tapping) to the frame bracing straps at 600mm centres nominal.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging Gap:

  • 0-10mm
A-D-AD-S-S4 image
WALL TYPE: Steel stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frame screwed to boxed studs with packing steel shims at 600mm centres nominal.
  • Steel studs to be screwed (14g x 125mm self tapping) to the frame bracing straps at 600mm centres nominal.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging Gap:

  • 0-10mm
A-D-AD-S-S5 image

Pacific AD300 Acoustic Door Set STC/Rw 40

WALL TYPE: Timber stud
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Fasteners:

  • Frame - Either nailed (75 x 3.2mm) or screwed (10g x 75mm) at 600mm centres nominal. Two fixings per location.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.
  • Pryda Jamb-fixa brackets Type JFB100 at 500mm centres may be used.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-T-T1 image
WALL TYPE: Timber stud
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Recommended Fasteners:

  • Frame - Either nailed (75 x 3.2mm) or screwed (10g x 75mm) at 600mm centres nominal. Two fixings per location.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.
  • Pryda Jamb-fixa brackets Type JFB100 at 500mm centres may be used.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-T-T2 image
WALL TYPE: Timber stud
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Recommended Fasteners:

  • Frame - Either nailed (75 x 3.2mm) or screwed (10g x 75mm) at 600mm centres nominal. Two fixings per location.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.
  • Pryda Jamb-fixa brackets Type JFB100 at 500mm centres may be used.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-T-T3 image
WALL TYPE: Timber stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Folded steel connection plates (as shown) to be supplied with frames.
  • Hook onto frame bracing straps and nail or screw to timber studs.
  • Frame connection plates either clouts (30 x 2.5mm gib clouts) or screw fixed.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - single central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • Not applicable
A-D-AD-S-T1 image
WALL TYPE: Timber stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Framing stud No.1 screwed to jamb.
  • Connection to stud No.2 via rebated nail on plates. One fastener per location except at bottom where two fasteners are required.
  • Frame to be screw fixed (10g x 50mm self tapping) at 600mm nominal centres. Two fasteners per location where applicable.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • Not applicable
A-D-AD-S-T2 image
WALL TYPE: Timber stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frame screwed to stud through packing between stud and shims.
  • Frame to be screw fixed (10g x 50mm self tapping) at 600mm nominal centres. Two fasteners per location where applicable.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-S-T3 image
WALL TYPE: Timber stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frames may be screwed directly to studs either through the stud and into the frame bracing straps or through the frame into the timber stud at 600mm centres nominal.
  • Frame to be screw fixed (10g x 50mm self tapping) at 600mm centres nominal. Two fasteners per location where applicable.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • Not applicable
A-D-AD-S-T4 image
WALL TYPE: Timber stud
FRAME TYPE: Steel, 2-part
A-D-2 Part-S-T1 image
WALL TYPE: Masonry
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Fasteners:

  • Frame - M8 or M10 'Ramset' Dynabolts at 600mm centres nominal and near hinges. Fixings on or near centre of frame jamb.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - single central fastener required

Wedging gap:

  • 0-10mm
A-D-AD-T-M image
WALL TYPE: Masonry
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Jamb fixing at 600mm centres minimum
  • Expansion anchors eg. M10 countersunk 'Ramset' Dynabolts
  • M12 countersunk masonry screwbolts

Head Fixing (minimum):

  • Single door - none required
  • Paired door - single central fastener required

Wedging Gap:

  • 0-10mm
A-D-AD-S-M image
WALL TYPE: Steel stud
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Fasteners:

  • Frame - Screwed (10g x 50mm self tapping) at 600mm centres nominal. Minimum of one screw per location.
  • Frames may also be installed by screw fixing the steel studs to the back of the timber frame during wall construction.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-T-S1 image
WALL TYPE: Steel stud
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Recommended Fasteners:

  • Frame - Screwed (10g x 50mm self tapping) at 600mm centres nominal and near hinges. Two screws per location
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-T-S2 image
WALL TYPE: Steel stud
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Recommended Fasteners:

  • Frame - Screwed (10g x 50mm self tapping) at 600mm centres nominal. Minimum of one screw per location. Frames may also be installed by screw fixing the steel studs to the back of the timber frame during wall construction.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-T-S3 image
WALL TYPE: Steel stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frame screwed to boxed stud at 600mm centres nominal with self tapping screws.
  • Steel studs may be riveted (steel pop rivets) or screwed (9g x 45mm self tapping) to the frame bracing straps at 600mm centres nominal.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • Not applicable
A-D-AD-S-S1 image
WALL TYPE: Steel stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frame screwed to boxed stud at 600mm centres nominal with self tapping screws.
  • Steel studs may be riveted (steel pop rivets) or screwed (9g x 45mm self tapping) to the frame bracing straps at 600mm centres nominal.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • Not applicable
A-D-AD-S-S2 image
WALL TYPE: Steel stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frame screwed to boxed studs with packing steel shims at 600mm centres nominal.
  • Steel studs may be riveted (steel pop rivets) or screwed (9g x 45mm self tapping) to the frame bracing straps at 600mm centres nominal.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging Gap:

  • 0-10mm
A-D-AD-S-S3 image
WALL TYPE: Steel stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frame screwed to boxed studs with packing steel shims at 600mm centres nominal.
  • Steel studs to be screwed (9g x 75mm self tapping) to the frame bracing straps at 600mm centres nominal.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging Gap:

  • 0-10mm
A-D-AD-S-S4 image
WALL TYPE: Steel stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frame screwed to boxed studs with packing steel shims at 600mm centres nominal.
  • Steel studs to be screwed (14g x 125mm self tapping) to the frame bracing straps at 600mm centres nominal.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging Gap:

  • 0-10mm
A-D-AD-S-S5 image

Pacific AFD300 Acoustic Door Set STC/Rw 40

WALL TYPE: Timber stud
FRAME TYPE: Timber

Frame materials available:

  • Hardwood timber - Min density 650kg/m3
  • 42 mm or 30 mm timber jamb thickness

Fasteners:

  • Frame - Either nailed (75 x3.2mm) or screwed (10g x 75mm) at 60mm centres nominal. Two fixings per location.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.
  • Pryda Jamb-fixa brackets type JFB100 at 500mm centres may be used.

Head Fixing

  • Single door - none required.
  • Paired door - double central fastener required.

Stud Size

  • Stud to suit acoustic wall system of equal or greater rating required.

Wedging gap:

  • 0-10mm
A-D-AFD-T-T1 image
WALL TYPE: Timber stud
FRAME TYPE: Timber

Frame materials available:

  • Hardwood timber - Min density 650kg/m3
  • 42 mm or 30 mm timber jamb thickness

Fasteners:

  • Frame - Either nailed (75 x3.2mm) or screwed (10g x 75mm) at 60mm centres nominal. Two fixings per location.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.
  • Pryda Jamb-fixa brackets type JFB100 at 500mm centres may be used.

Head Fixing

  • Single door - none required.
  • Paired door - double central fastener required.

Stud Size

  • Stud to suit acoustic wall system of equal or greater rating required.

Wedging gap:

  • 0-10mm
A-D-AFD-T-T2 image
WALL TYPE: Timber stud
FRAME TYPE: Timber

Frame materials available:

  • Hardwood timber - Min density 650kg/m3
  • 42 mm or 30 mm timber jamb thickness

Fasteners:

  • Frame - Either nailed (75 x3.2mm) or screwed (10g x 75mm) at 60mm centres nominal. Two fixings per location.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.
  • Pryda Jamb-fixa brackets type JFB100 at 500mm centres may be used.

Head Fixing

  • Single door - none required.
  • Paired door - double central fastener required.

Stud Size

  • Stud to suit acoustic wall system of equal or greater rating required.

Wedging gap:

  • 0-10mm
A-D-AFD-T-T3 image
WALL TYPE: Masonry
FRAME TYPE: Timber

Frame materials available:

  • Hardwood timber - Min density 650kg/m3
  • 42 mm or 30 mm timber jamb thickness

Fasteners:

  • Frame - M8 or M10 'Ramset' Dynabolts at 600mm centres nominal and near hinges. Fixings on or near centre of frame jamb.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.

Head Fixing

  • Single door - none required.
  • Paired door - single central fastener required.

Wedging gap:

  • 0-10mm
A-D-AFD-T-M image

Pacific AD400 Acoustic Door Set STC/Rw 43

WALL TYPE: Timber stud
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Fasteners:

  • Frame - Either nailed (75 x 3.2mm) or screwed (10g x 75mm) at 600mm centres nominal. Two fixings per location.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.
  • Pryda Jamb-fixa brackets Type JFB100 at 500mm centres may be used.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-T-T1 image
WALL TYPE: Timber stud
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Recommended Fasteners:

  • Frame - Either nailed (75 x 3.2mm) or screwed (10g x 75mm) at 600mm centres nominal. Two fixings per location.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.
  • Pryda Jamb-fixa brackets Type JFB100 at 500mm centres may be used.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-T-T2 image
WALL TYPE: Timber stud
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Recommended Fasteners:

  • Frame - Either nailed (75 x 3.2mm) or screwed (10g x 75mm) at 600mm centres nominal. Two fixings per location.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.
  • Pryda Jamb-fixa brackets Type JFB100 at 500mm centres may be used.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-T-T3 image
WALL TYPE: Timber stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Folded steel connection plates (as shown) to be supplied with frames.
  • Hook onto frame bracing straps and nail or screw to timber studs.
  • Frame connection plates either clouts (30 x 2.5mm gib clouts) or screw fixed.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - single central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • Not applicable
A-D-AD-S-T1 image
WALL TYPE: Timber stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Framing stud No.1 screwed to jamb.
  • Connection to stud No.2 via rebated nail on plates. One fastener per location except at bottom where two fasteners are required.
  • Frame to be screw fixed (10g x 50mm self tapping) at 600mm nominal centres. Two fasteners per location where applicable.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • Not applicable
A-D-AD-S-T2 image
WALL TYPE: Timber stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frame screwed to stud through packing between stud and shims.
  • Frame to be screw fixed (10g x 50mm self tapping) at 600mm nominal centres. Two fasteners per location where applicable.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-S-T3 image
WALL TYPE: Timber stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frames may be screwed directly to studs either through the stud and into the frame bracing straps or through the frame into the timber stud at 600mm centres nominal.
  • Frame to be screw fixed (10g x 50mm self tapping) at 600mm centres nominal. Two fasteners per location where applicable.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • Not applicable
A-D-AD-S-T4 image
WALL TYPE: Timber stud
FRAME TYPE: Steel, 2-part
A-D-2 Part-S-T1 image
WALL TYPE: Masonry
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Fasteners:

  • Frame - M8 or M10 'Ramset' Dynabolts at 600mm centres nominal and near hinges. Fixings on or near centre of frame jamb.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - single central fastener required

Wedging gap:

  • 0-10mm
A-D-AD-T-M image
WALL TYPE: Masonry
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Jamb fixing at 600mm centres minimum
  • Expansion anchors eg. M10 countersunk 'Ramset' Dynabolts
  • M12 countersunk masonry screwbolts

Head Fixing (minimum):

  • Single door - none required
  • Paired door - single central fastener required

Wedging Gap:

  • 0-10mm
A-D-AD-S-M image
WALL TYPE: Steel stud
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Fasteners:

  • Frame - Screwed (10g x 50mm self tapping) at 600mm centres nominal. Minimum of one screw per location.
  • Frames may also be installed by screw fixing the steel studs to the back of the timber frame during wall construction.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-T-S1 image
WALL TYPE: Steel stud
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Recommended Fasteners:

  • Frame - Screwed (10g x 50mm self tapping) at 600mm centres nominal and near hinges. Two screws per location
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-T-S2 image
WALL TYPE: Steel stud
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Recommended Fasteners:

  • Frame - Screwed (10g x 50mm self tapping) at 600mm centres nominal. Minimum of one screw per location. Frames may also be installed by screw fixing the steel studs to the back of the timber frame during wall construction.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-T-S3 image
WALL TYPE: Steel stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frame screwed to boxed stud at 600mm centres nominal with self tapping screws.
  • Steel studs may be riveted (steel pop rivets) or screwed (9g x 45mm self tapping) to the frame bracing straps at 600mm centres nominal.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • Not applicable
A-D-AD-S-S1 image
WALL TYPE: Steel stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frame screwed to boxed stud at 600mm centres nominal with self tapping screws.
  • Steel studs may be riveted (steel pop rivets) or screwed (9g x 45mm self tapping) to the frame bracing straps at 600mm centres nominal.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • Not applicable
A-D-AD-S-S2 image
WALL TYPE: Steel stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frame screwed to boxed studs with packing steel shims at 600mm centres nominal.
  • Steel studs may be riveted (steel pop rivets) or screwed (9g x 45mm self tapping) to the frame bracing straps at 600mm centres nominal.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging Gap:

  • 0-10mm
A-D-AD-S-S3 image
WALL TYPE: Steel stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frame screwed to boxed studs with packing steel shims at 600mm centres nominal.
  • Steel studs to be screwed (9g x 75mm self tapping) to the frame bracing straps at 600mm centres nominal.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging Gap:

  • 0-10mm
A-D-AD-S-S4 image
WALL TYPE: Steel stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frame screwed to boxed studs with packing steel shims at 600mm centres nominal.
  • Steel studs to be screwed (14g x 125mm self tapping) to the frame bracing straps at 600mm centres nominal.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging Gap:

  • 0-10mm
A-D-AD-S-S5 image

Pacific AD500 Acoustic Door Set STC/RW 50

WALL TYPE: Timber stud
FRAME TYPE: Timber

Frame materials available:

  • Radiata Pine
  • Hardwood timber

Fasteners:

  • Frame to be screw fixed at 400mm centres nominal. Two fixings per location (10g x 75mm and 14g x 125mm)
  • Architraves optional

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-T-T4 image
WALL TYPE: Timber stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 2.0mm
  • Cold-rolled galvanised - 2.0mm

Fasteners:

  • Frame to be screw fixed at 400mm centres nominal. Two fixings per location (10g x 75mm and 14g x 125mm)
  • Architraves optional

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-S-T5 image

Non Fire Rated Interconnecting Doors

WALL TYPE: Masonry
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Jamb fixing at 600mm centres minimum
  • Expansion anchors eg. M10 countersunk 'Ramset' Dynabolts
  • M12 countersunk masonry screwbolts

Head Fixing (minimum):

  • Single door - none required
  • Paired door - single central fastener required

Wedging Gap:

  • 0-10mm
A-D-AD-TC-M image
WALL TYPE: Masonry
FRAME TYPE: Steel, 1-part

Frame materials available:

  • Timber (any species), Pine clear standard

Fasteners:

  • Frame - Either nailed (75 x 3.2mm) or screwed (10g x 75mm) at 600mm centres nominal. Two fixings per location.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.
  • Pryda Jamb-fixa brackets Type JFB100 at 500mm centres may be used.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - single central fastener required (per head)

Wedging gap:

  • 0-10mm
A-D-AD-TS-M image
WALL TYPE: Steel stud
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Fasteners:

  • Frame - Either nailed (75 x 3.2mm) or screwed (10g x 75mm) at 600mm centres nominal. Two fixings per location.

Stops - nailed (50 x 3.2mm) at 200mm centres.

Architrave - nailed (50 x 3.2mm) at 400mm centres.

  • Pryda Jamb-fixa brackets Type JFB100 at 500mm centres may be used.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Wedging gap:

  • 0-10mm
A-D-AD-TC-T image
WALL TYPE: Steel stud
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Fasteners:

  • Frame - Either nailed (75 x 3.2mm) or screwed (10g x 75mm) at 600mm centres. Two fixings per location.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.
  • Pryda Jamb-fixa brackets Type JFB100 at 500mm centres may be used.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required (per head)

Stud size:

  • Ex 100 x 50 minimum

Wedging gap:

  • 0-10mm
A-D-AD-TS-T image
WALL TYPE: Steel stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frames may be screwed directly to studs either through the stud and into the frame bracing straps or through the frame into the timber stud at 600mm centres nominal.
  • Frame to be screw fixed (10g x 50mm self tapping) at 600mm centres nominal. Two fasteners per location where applicable.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Ex 100 x 50 minimum

Wedging gap:

  • 0-10mm
A-D-AD-SC-T image
WALL TYPE: Steel stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frames may be screwed directly to studs either through the stud and into the frame bracing straps or through the frame into the timber stud at 600mm centres nominal.
  • Frame to be screw fixed (10g x 50mm self tapping) at 600mm centres nominal. Two fasteners per location where applicable.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Ex 100 x 50 minimum

Wedging gap:

  • 0-10mm
A-D-AD-SS-T image

Fire Rated Interconnecting Doors

WALL TYPE: Timber stud
FRAME TYPE: Timber

Frame materials available:

  • Hardwood timber - Min. density 580kg/m≥ (minimum thickness is 30mm)

Fasteners:

  • Frame - Either nailed (75 x 3.2mm) or screwed (10g x 75mm) at 600mm centres nominal. Two fixings per location.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.
  • Pryda Jamb-fixa brackets Type JFB100 at 500mm centres may be used to fix profiles A & B to approved walls.

Stud size:

  • Ex 100 x 50 minimum.

Wedging gap:

  • 0-10mm
A-D-SPA40FR60-TC-T image
WALL TYPE: Timber stud
FRAME TYPE: Timber

Frame materials available:

  • Hardwood timber - Min. density 580kg/m≥ (minimum thickness is 30mm)

Fasteners:

  • Frame - Either nailed (75 x 3.2mm) or screwed (10g x 75mm) at 600mm centres nominal. Two fixings per location.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.
  • Pryda Jamb-fixa brackets Type JFB100 at 500mm centres may be used to fix to approved walls.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Ex100 x 50 minimum.

Wedging gap:

  • 0-10mm
A-D-SPA40FR60-TS-T image
WALL TYPE: Timber stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frame to be screw fixed (10g self tapping) at 600mm centres nominal. Two fasteners per location where applicable.

Head Fixing (minimum)

  • Single door - none required
  • Paired door - single central fixing required

Stud Size:

  • Ex 100 x50 minimum

Wedging gap:

  • 0-10mm
A-D-SPA40FR60-SC-T image
WALL TYPE: Masonry
FRAME TYPE: Timber

Frame materials available:

  • Hardwood timber - Min. density 580kg/m≥ (minimum thickness is 30mm)

Fasteners:

  • Frame - M8 or M10 'Ramset' Dynabolts at 600mm centres nominal. Fixings on or near centre of frame jamb.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - single central fastener required

Wedging gap:

  • 0-15mm
A-D-SPA40FR60-TC-M image
WALL TYPE: Masonry
FRAME TYPE: Timber

Frame materials available:

  • Hardwood timber - Min. density 580kg/m≥ (minimum thickness is 30mm)

Fasteners:

  • Frame - M8 or M10 'Ramset' Dynabolts at 600mm centres nominal. Fixings on or near centre of frame jamb.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - single central fastener required

Wedging gap:

  • 0-15mm
A-D-SPA40FR60-TS-M image
WALL TYPE: Masonry
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Jamb fixing at 600mm centres nominal
  • Expansion anchors eg. M10 countersunk 'Ramset' Dynabolts
  • M12 countersunk masonry screwbolts

Head Fixing (minimum):

  • Single door - none required
  • Paired door - single central fastener required

Wedging gap:

  • 0-10mm
A-D-SPA40FR60-SC-M image
WALL TYPE: Steel stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Fasteners:

  • Frame screwed to boxed stud at 600mm centres nominal with self tapping screws.
  • Steel studs may be riveted (steel pop rivets) or screwed (9g x 45mm self tapping) to the frame bracing straps.

Head Fixing (minimum):

  • Single Door - none required
  • Paired door - single central fastener required

Stud size:

92 x 34mm minimum of 0.55 SMG gauge

Wedging gap:

  • 0-10mm
A-D-SPA40FR60-SC-S image

Pacific Single Glazed Acoustic Windows SPA35-AW

WALL TYPE: Timber stud
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Recommended Fasteners:

  • Timber & steel studs - Screwed (10g x 50mm self tapping) at 600mm centres nominal. Minimum of one screw per location.
  • Steel stud only - Frames may also be installed by screw fixing the steel studs to the back of the timber frame during wall construction.

Stud Size:

  • Stud to suit acoustic wall system of equal or greater rating required.

Wedging gap:

  • 0-10mm
A-W-SPA35-39-T-T image
WALL TYPE: Masonry
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Recommended Fasteners:

  • Jamb fixing at 600mm centres nominal
  • Expansion anchors eg. M10 countersunk 'Ramset' Dynabolts
  • M12 countersunk masonry screwbolts
  • Architrave -nailed (50 x 3.2mm) at 400mm centres.

Wedging gap:

  • 0-10mm
A-W-SPA35-39-M image

Pacific Single Glazed Acoustic Windows SPA39-AW

WALL TYPE: Timber stud
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Recommended Fasteners:

  • Timber & steel studs - Screwed (10g x 50mm self tapping) at 600mm centres nominal. Minimum of one screw per location.
  • Steel stud only - Frames may also be installed by screw fixing the steel studs to the back of the timber frame during wall construction.

Stud Size:

  • Stud to suit acoustic wall system of equal or greater rating required.

Wedging gap:

  • 0-10mm
A-W-SPA35-39-T-T image
WALL TYPE: Masonry
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Recommended Fasteners:

  • Jamb fixing at 600mm centres nominal
  • Expansion anchors eg. M10 countersunk 'Ramset' Dynabolts
  • M12 countersunk masonry screwbolts
  • Architrave -nailed (50 x 3.2mm) at 400mm centres.

Wedging gap:

  • 0-10mm
A-W-SPA35-39-M image

Pacific Double Glazed Acoustic Windows SPA48-AW

WALL TYPE: Timber stud
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Recommended Fasteners:

  • Timber & steel studs - Screwed (10g x 50mm self tapping) at 600mm centres nominal. Minimum of one screw per location.
  • Steel stud only - Frames may also be installed by screw fixing the steel studs to the back of the timber frame during wall construction.

Stud Size:

  • Stud to suit acoustic wall system of equal or greater rating required.

Wedging gap:

  • 0-10mm
A-W-SPA48AW-48-T-S image
WALL TYPE: Masonry
FRAME TYPE: Timber

Frame materials available:

  • Timber (any species), Pine clear standard

Recommended Fasteners:

  • Jamb fixing at 600mm centres nominal
  • Expansion anchors eg. M10 countersunk 'Ramset' Dynabolts
  • M12 countersunk masonry screwbolts
  • Architrave -nailed (50 x 3.2mm) at 400mm centres.

Wedging gap:

  • 0-10mm
A-W-SPA48AW-48-M image

Pacific Forster Fire Acoustic Window

WALL TYPE: Timber stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • Forster extruded profile

Fasteners:

  • 12g screws at 450mm centres maximum

Wedging gap:

  • 0-10mm
F-W-PSW60-T image
WALL TYPE: Timber stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • Forster extruded profile

Fasteners:

  • 12g screws at 450mm centres maximum

Wedging gap:

  • 0-10mm
F-W-PSW60-T-E-1 image
WALL TYPE: Timber stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • Forster extruded profile

Fasteners:

  • 12g screws at 450mm centres maximum

Wedging gap:

  • 0-10mm
F-W-PSW60-T-E-2 image
WALL TYPE: Timber stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • Forster extruded profile

Fasteners:

  • 12g screws at 450mm centres maximum

Wedging gap:

  • 0-10mm
F-W-PSW60-T-E-3 image
WALL TYPE: Masonry
FRAME TYPE: Steel, 1-part

Frame materials available:

  • Forster extruded profile

Fasteners:

  • M8 masonry bolts at 450mm centres maximum

Wedging gap:

  • 0-10mm
F-W-PSW60-M image
WALL TYPE: Masonry
FRAME TYPE: Steel, 1-part

Frame materials available:

  • Forster extruded profile

Fasteners:

  • M8 masonry bolts at 450mm centres maximum

Wedging gap:

  • 0-10mm
F-W-PSW60-M-E-1 image
WALL TYPE: Masonry
FRAME TYPE: Steel, 1-part

Frame materials available:

  • Forster extruded profile

Fasteners:

  • M8 masonry bolts at 450mm centres maximum

Wedging gap:

  • 0-10mm
F-W-PSW60-M-E-2 image
WALL TYPE: Masonry
FRAME TYPE: Steel, 1-part

Frame materials available:

  • Forster extruded profile

Fasteners:

  • M8 masonry bolts at 450mm centres maximum

Wedging gap:

  • 0-10mm

Note: Projecting sill may be removed for flush appearance, but removal may cause staining under windows from dirt washed off sill.

F-W-PSW60-M-E-3 image
WALL TYPE: Steel stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • Forster extruded profile

Fasteners:

  • 12g screws at 450mm centres maximum

Wedging gap:

  • 0-10mm
F-W-PSW60-S image