Non Fire Rated Interconnecting Doors Installation
This tool is designed to filter the available results as you search. Once you have applied a filter, you may need to reset the filter to be able to see all other available options.
Please note: Hardware is not included with our doors. However, we are pleased to help in sourcing high-quality hardware from ASSA ABLOY at an additional cost.
For BPIR Documents related to ASSA ABLOY hardware, please see: ASSA ABLOY
For hardware from other suppliers, please refer to the individual hardware supplier for information.
Installation wall framing requirements
Non Fire Rated Interconnecting Doors
Frame materials available:
- EGZ - 1.6mm
- Cold rolled galvanized - 1.6mm
- Stainless Steel - 1.5mm
Fasteners:
- Jamb fixing at 600mm centres minimum
- Expansion anchors eg. M10 countersunk 'Ramset' Dynabolts
- M12 countersunk masonry screwbolts
Head Fixing (minimum):
- Single door - none required
- Paired door - single central fastener required
Wedging Gap:
- 0-10mm
Frame materials available:
- Timber (any species), Pine clear standard
Fasteners:
- Frame - Either nailed (75 x 3.2mm) or screwed (10g x 75mm) at 600mm centres nominal. Two fixings per location.
- Stops - nailed (50 x 3.2mm) at 200mm centres.
- Architrave - nailed (50 x 3.2mm) at 400mm centres.
- Pryda Jamb-fixa brackets Type JFB100 at 500mm centres may be used.
Head Fixing (minimum):
- Single door - none required
- Paired door - single central fastener required (per head)
Wedging gap:
- 0-10mm
Frame materials available:
- Timber (any species), Pine clear standard
Fasteners:
- Frame - Either nailed (75 x 3.2mm) or screwed (10g x 75mm) at 600mm centres nominal. Two fixings per location.
Stops - nailed (50 x 3.2mm) at 200mm centres.
Architrave - nailed (50 x 3.2mm) at 400mm centres.
- Pryda Jamb-fixa brackets Type JFB100 at 500mm centres may be used.
Head Fixing (minimum):
- Single door - none required
- Paired door - double central fastener required
Wedging gap:
- 0-10mm
Frame materials available:
- Timber (any species), Pine clear standard
Fasteners:
- Frame - Either nailed (75 x 3.2mm) or screwed (10g x 75mm) at 600mm centres. Two fixings per location.
- Stops - nailed (50 x 3.2mm) at 200mm centres.
- Architrave - nailed (50 x 3.2mm) at 400mm centres.
- Pryda Jamb-fixa brackets Type JFB100 at 500mm centres may be used.
Head Fixing (minimum):
- Single door - none required
- Paired door - double central fastener required (per head)
Stud size:
- Ex 100 x 50 minimum
Wedging gap:
- 0-10mm
Frame materials available:
- EGZ - 1.6mm
- Cold rolled galvanized - 1.6mm
- Stainless Steel - 1.5mm
Fasteners:
- Frames may be screwed directly to studs either through the stud and into the frame bracing straps or through the frame into the timber stud at 600mm centres nominal.
- Frame to be screw fixed (10g x 50mm self tapping) at 600mm centres nominal. Two fasteners per location where applicable.
Head Fixing (minimum):
- Single door - none required
- Paired door - double central fastener required
Stud size:
- Ex 100 x 50 minimum
Wedging gap:
- 0-10mm
Frame materials available:
- EGZ - 1.6mm
- Cold rolled galvanized - 1.6mm
- Stainless Steel - 1.5mm
Fasteners:
- Frames may be screwed directly to studs either through the stud and into the frame bracing straps or through the frame into the timber stud at 600mm centres nominal.
- Frame to be screw fixed (10g x 50mm self tapping) at 600mm centres nominal. Two fasteners per location where applicable.
Head Fixing (minimum):
- Single door - none required
- Paired door - double central fastener required
Stud size:
- Ex 100 x 50 minimum
Wedging gap:
- 0-10mm