Pacific F0.5 Door Set -/30/30sm Installation

 

This tool is designed to filter the available results as you search. Once you have applied a filter, you may need to reset the filter to be able to see all other available options.

To see our installation videos please click here.

Installation wall framing requirements

Pacific F0.5 Door Set -/30/30sm

WALL TYPE: Timber stud
FRAME TYPE: Timber

Frame materials available:

  • Radiata pine or denser, minimum 30mm thick (standard

Fasteners:

  • Frame - either nailed (75x3.2mm) or screwed (10gx75mm) at 600mm centres. Two nails or screws per location.
  • Stops - nailed (50x3.2mm) at 200mm centres.
  • Architrave - nailed (50x3.2mm) at 400mm centres.
  • Pryda Jamb-fixa brackets Type JBF100 at 500mm centres.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Ex 75x50mm minimum

Wedging gap:

  • 0-6mm
F-D-F.05-T-T-1 image
WALL TYPE: Timber stud
FRAME TYPE: Timber

Frame materials available:

  • Radiata pine or denser, minimum 30mm thick (standard thicknesses are 30mm or 42mm)

Fasteners:

  • Frame - either nailed (75x3.2mm) or screwed (10gx75mm) at 600mm centres. Two nails or screws per location.
  • Stops - nailed (50x3.2mm) at 200mm centres.
  • Architrave - nailed (50x3.2mm) at 400mm centres.
  • Pryda Jamb-fixa brackets Type JBF100 at 500mm centres.

Stud size:

  • ex 75x50mm minimum

Wedging gap:

  • 0-6mm
F-D-F.05-T-T-2 image
WALL TYPE: Timber stud
FRAME TYPE: Timber

Frame materials available:

  • Radiata pine or denser, minimum 30mm thick (standard thicknesses are 30mm or 42mm)

Fasteners:

  • Frame - either nailed (75x3.2mm) or screwed (10gx75mm) at 600mm centres. Two nails or screws per location.
  • Stops - nailed (50x3.2mm) at 200mm centres.
  • Architrave - nailed (50x3.2mm) at 400mm centres.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Ex 75x50mm minimum

Wedging gap:

  • 0-6mm
F-D-F.05-T-T-3 image
WALL TYPE: Timber stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanised - 1.6mm

Fasteners:

  • Folded steel connection plates (as shown) to be supplied with frames.
  • Hook onto frame bracing straps and nail or screw to timber studs.
  • Frame connection plates either clouts (30 x 2.5mm gib clouts) or screw fixed.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - single central fastener required

Stud size:

  • Ex 75x50 minimum

Wedging Gap:

  • Not applicable
F-D-F.05-S-T image
WALL TYPE: Masonry
FRAME TYPE: Timber

Frame materials available:

  • Radiata pine or denser, minimum 30mm thick (standard thicknesses are 30mm or 42mm)

Fasteners:

  • Frame - M8 'Ramset' Dynabolts at 600mm centres nominal.
  • Stops - nailed (50x3.2mm) at 200mm centres.
  • Architrave - nailed (50x3.2mm) at 400mm centres.

Head Fixing (minimum):

  • Single door - none required.
  • Paired door - single central fastener required.

Wedging gap:

  • 0-6mm.
F-D-F.05-T-M image
WALL TYPE: Masonry
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm

Fasteners:

  • Countersunk anchor method - Jamb fixings at 600mm centres nominal: M10 expansion anchors eg Dynabolt D10102F (as shown) or M12 masonry screwbolts. The length of bolts MUST be confirmed on site to suit the frame openings formed.

Head Fixing (minimum):

  • Single door - none required.
  • Paired door - single central fastener required.

Wedging Gap:

  • 0-15mm
F-D-F.05-S-M image
WALL TYPE: Steel stud
FRAME TYPE: Timber

Frame materials available:

  • Radiata pine or denser, minimum 30mm thick (standard thicknesses are 30mm or 42mm)

Fasteners:

  • Frame - either nailed (75x3.2mm) or screwed (10gx75mm) at 600mm centres. Two nails or screws per location.
  • Stops - nailed (50x3.2mm) at 200mm centres.
  • Architrave - nailed 50x3.2mm) at 400mm centres.
  • Pryda Jamb-fixa brackets Type JBF100 at 500mm centres.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Steel stud minimum 63mm, timber stud to match

Wedging gap:

  • 0-6mm
F-D-F.05-T-S-1 image
WALL TYPE: Steel stud
FRAME TYPE: Timber

Frame materials available:

  • Radiata pine or denser, minimum 30mm thick (standard thicknesses are 30mm or 42mm)

Fasteners:

  • Frame - either nailed (75x3.2mm) or screwed (10gx75mm) at 600mm centres. Two nails or screws per location.
  • Stops - nailed (50x3.2mm) at 200mm centres.
  • Architrave - nailed (50x3.2mm) at 400mm centres.
  • Pryda Jamb-fixa brackets Type JBF100 at 500mm centres.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Steel stud minimum 63mm, timber stud to match

Wedging gap:

  • 0-6mm
F-D-F.05-T-S-2 image
WALL TYPE: Steel stud
FRAME TYPE: Timber

Frame materials available:

  • Radiata pine or denser, minimum 30mm thick (standard thicknesses are 30mm or 42mm)

Fasteners:

  • Frame - either nailed (75x3.2mm) or screwed (10gx75mm) at 600mm centres. Two nails or screws per location.
  • Stops - nailed (50x3.2mm) at 200mm centres. Architrave - nailed 50x3.2mm) at 400mm centres.
  • Pryda Jamb-fixa brackets Type JBF100 at 500mm centres.

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Steel stud minimum 63mm, timber stud to match

Wedging gap:

  • 0-6mm
F-D-F.05-T-S-3 image