Pacific VP30HR Hinged Door Set -/30/30sm Installation
This tool is designed to filter the available results as you search. Once you have applied a filter, you may need to reset the filter to be able to see all other available options.
Please note: Hardware is not included with our doors. However, we are pleased to help in sourcing high-quality hardware from ASSA ABLOY at an additional cost.
For BPIR Documents related to ASSA ABLOY hardware, please see: ASSA ABLOY
For hardware from other suppliers, please refer to the individual hardware supplier for information.
Installation wall framing requirements
Pacific VP30HR Hinged Door Set -/30/30sm
Frame materials available:
- Hardwood of minimum density 580 kg/m3 (minimum thickness is 30mm)
Fasteners:
- Frame - Either nailed (75 x 3.2mm) or screwed (10g x 75mm) at 600mm centres. Two fixings per location.
- Stops - nailed (50 x 3.2mm) at 200mm centres.
- Architrave - nailed (50 x 3.2mm) at 400mm centres.
Head Fixing (minimum):
- Single door - none required
- Paired door - double central fastener required
Stud size:
- Ex 75 x 50 minimum.
Wedging gap:
- 0-15mm
Frame materials available:
- Hardwood of minimum density 580 kg/m3 (minimum thickness is 42mm)
Fasteners:
- Frame - Either nailed (75 x 3.2mm) or screwed (10g x 75mm) at 600mm centres nominal. Two fixings per location.
- Stops - nailed (50 x 3.2mm) at 200mm centres.
- Architrave - nailed (50 x 3.2mm) at 400mm centres.
- Pryda Jamb-fixa brackets Type JFB100 at 500mm centres may be used to fix profiles A & B to approved walls.
Stud size:
- Ex 75x50 minimum.
Wedging gap:
- 0-10mm
Frame materials available:
- Hardwood of minimum density 580 kg/m3 (minimum thickness is 30mm)
Fasteners:
- Frame - M8 or M10 'Ramset' Dynabolts at 600mm centres nominal. Fixings on or near centre of frame jamb.
- Stops - nailed (50 x 3.2mm) at 200mm centres.
- Architrave -nailed (50 x 3.2mm) at 400mm centres.
Head Fixing (minimum):
- Single door - none required
- Paired door - single central fastener required
Wedging gap:
- 0-15mm
Frame materials available:
- Hardwood of minimum density 580 kg/m3 (minimum thickness is 30mm)
Fasteners:
- Frame - Screwed (10g self tapping) at 600mm centres nominal. Minimum of one screw per location. Frames may also be installed by screw fixing the steel studs to the back of the timber frame during wall construction.
- Stops - nailed (50 x 3.2mm) at 200mm centres.
- Architrave - nailed (50 x 3.2mm) at 400mm centres.
Head Fixing (minimum):
- Single door - none required
- Paired door - double central fastener required
Stud size:
- 65 x 34mm minimum of 0.55 MSG gauge.
Wedging gap:
- 0-10mm