Pacific F0.5-AP Access Panel -/30/30sm Installation

 

This tool is designed to filter the available results as you search. Once you have applied a filter, you may need to reset the filter to be able to see all other available options.

To see our installation videos please click here.

Installation wall framing requirements

Pacific F0.5-AP Access Panel -/30/30sm

WALL TYPE: Timber stud
FRAME TYPE: Timber

Frame materials available:

  • Radiata pine or denser

Architraves:

  • Radiata pine (or denser) timber
  • Thickness 12mm minimum

Fasteners:

  • Frame - Screwed (10g x 50mm self tapping) at 600mm centres and near hinges. Two screws per location.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.

Wedging gap:

  • 0-10mm
F-P-FRR30-T-T image
WALL TYPE: Masonry
FRAME TYPE: Timber

Frame materials available:

  • Radiata pine or denser

Architraves:

  • Radiata pine (or denser) timber
  • Thickness 12mm minimum

Fasteners:

  • Frame - Screwed (10g x 50mm self tapping) at 600mm centres and near hinges. Two screws per location.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.

Wedging gap:

  • 0-10mm
F-P-FRR30-T-M image
WALL TYPE: Steel stud
FRAME TYPE: Timber

Frame materials available:

  • Radiata pine or denser

Architraves:

  • Radiata pine (or denser) timber
  • Thickness 12mm minimum

Fasteners:

  • Frame - Screwed (10g x 50mm self tapping) at 600mm centres and near hinges. Two screws per location.
  • Stops - nailed (50 x 3.2mm) at 200mm centres.
  • Architrave - nailed (50 x 3.2mm) at 400mm centres.

Wedging gap:

  • 0-10mm
F-P-FRR30-T-S image