The Pacific SPS1-E doorset is a detention or commercial security door, resistant to physical attack using hand tools, levers and battering rams from either face. The SPS1-E includes features designed to increase impact resistance and durability in high-use situations. The door leaf is a reinforced solid core panel, fully encapsulated in steel sheet with seam-welded edges, hung in a steel frame.
Product features:
Applications:
The Pacific SPS1-E door set is a detention or commercial security door, resistant to physical attack using hand tools, levers and battering rams from either face. The SPS1-E includes features designed to increase impact resistance and durability in high-use situations.
The door leaf is a reinforced solid core panel, fully encapsulated in steel sheet with seam-welded edges, hung in a steel frame.
A fire-rated version of the SPS1-E is available. Please note installation and other restrictions which apply
Most common applications include:
The door set is suitable for both interior and exterior use.
The thickness of the SPS1-E door leaf is 50mm with an approximate leaf weight of 80kg/m2
Wall Type | Fire Resistance Rating (FRR) | Door Application | Max Leaf Height (mm) | Max Leaf Width (mm) |
Timber Stud3 Masonry | -/90/60 (sm) | Single | 2350 | 1150 |
Notes:
The SPS1-E fire rated door set can only be installed fully grouted into a concrete/masonry wall opening.
A timber stud subframe can be factory fitted to the main frame for connection to a timber stud security wall.
Frames may be installed during or after construction of masonry walls. Several proven connection systems are available.
The SPS1-E is fully encapsulated in steel sheet.
Leaf Edges
The SPS1-E has seam welded edges as shown below.
Meeting Stile
This door set is not available as a pair.
A rebated meeting stile is available upon request. Please contact Pacific Doors to discuss your requirements.
Timber Frame
This door set is only available in a steel frame.
Steel Frame
The steel frame profiles listed below are available for the SPS1-E door set
Standard frames are three-sided only with no sill. Four-sided frames and/or custom sills may be available on request. Timber sills are not available on fire doorsets. For more in depth information on frame profiles and sizes, please see our Installation Instructions.
Glazing Type | Maximum Glazed Area | Max Height (mm) | Max Width (mm) | Glazing Bead | FRR with Vision Panel | ||
Per VP | Total | Steel Bead | Up to 0.065m2 | Over 0.065m2 | |||
Firelam | 0.091m2 | 0.182m2 | 700 | 700 | √ | -/90/60 | -/90/- |
The standard glazing system provides a flush attack face and steel beading fixed via tamper resistant screws on the inside face.
Standard Vision Panel Cross Sections
Steel Bead
This door leaf has a thermal insulation rating (R-value) of 0.616 Km2/W.
The SPS1-E door set was subjected to 30 impacts from an SPS1 door leaf (weighing 110kg) at 4.8m/s, in the direction of opening of the door. This was intended to simulate using another door leaf as a battering ram. The door remained in its frame and locked at the end of the test, with paneling damaged but not broken.
Full mortise 4½” x 4½“ Institutional Hinges are standard (material is Stainless Steel 304).
The leaf is solid core and therefore most surface mounted or mortised devices can be connected to it such as:
A wide range of electronic locks may be accommodated including electromagnet clamps, shearlocks, and electric strikes.
Locking systems with multiple bolts including top and bottom bolts, internally fitted to the SPS1-E door set, are available from Pacific Door Systems.
The fire-rated SPS1-E may be fitted with a range of security hardware, including locks with steel components, any closers, pull handles and minor items of hardware provided they are non-combustible and fixed with steel fasteners. Note that fitting of deadlocks and other non-self-latching hardware will make the door set non-compliant in respect to the standard NZS 4520 Fire-resistant door sets.
The door has a maximum hold-open angle of 180o. Electromagnet clamps are standard hold-open devices.
Fully mortised devices, which fully conceal cables, are recommended (such as Von Duprin EPT-218). Hinges with integral wiring are also available.
Kickplates are not generally required on this door set.
Optional, stainless steel mesh inserted into the door core and faced each side with louvre grilles (maximum 200x200mm). Not available for fire-rated SPS1-E.
A hinged, latching food hatch may be fitted to suit clients' requirements. Not available for fire-rated SPS1-E.
Overpanels are not applicable for this door set.