Product Options

  • The thickness of the Armashield-FR door leaf is 48mm with an approximate leaf weight of 80kg/m2

    Wall TypeFire Resistance Rating (FRR)Door ApplicationMax Leaf
    Height (mm)
    Max Leaf
    Width (mm)
    Masonry-/120/-Single21681021
    Masonry-/90/-Single27001200

    Notes:

    1. Sizes outside of this range are possible, but this will affect the fire rating of the door set.
    2. Minimum width for a fire door leaf is governed by the need to fit a compliant closer. Typically, 400 mm is the practical minimum.

    Wall Types

    Installation of the fire-rated Armashield-FR requires a fully grouted steel frame in a masonry or precast concrete wall of the appropriate fire rating.

  • Leaf Facings

    All steel leaf with attack face in 6mm steel. Non attack (inside) face is a removable light gauge steel panel.

    Leaf Edges

    The Armashield-FR has leaf edges edges as shown below.

    Meeting Stile

    This door set is not available as a pair.

  • Timber Frame

    This door set is only available in a steel frame.

     

    Steel Frame

    The steel frame profiles listed below are available for the Armashield-FR door set.

    Standard frames are three-sided only with no sill. Four-sided frames and/or custom sills may be available on request. Timber sills are not available on fire doorsets. For more in depth information on frame profiles and sizes, please see our Installation Instructions.

  • Glazing Type Maximum Glazed Area   Max Height (mm) Max Width (mm) Steel Glazing Bead
    FRR with Vision Panel
      Per VP Total Up to 0.065m2 Over 0.065m2
    Firelam (2) 0.091m2 0.091m2 700 130 -/120/- -/120/-
    Pyran S (2) 1.08m2 2.16m2 1200 900 -/90/- -/90/-
    NOVOLAY Secure BR4 NS / 1.5.4 (4) 0.42m2 0.84m2 700 600 -/60/- -/60/-

    Notes:

    1. Please note that the height and width of the vision panel must still fall within the maximum glazed area.
    2. This glazing is fire glazing, not security glazing. For apertures more than 200 mm wide we recommend steel bars for security
    3. Blast, Attack and Ballistic ratings may be affected if the door has a vision panel.
    4. Mass of door leaf not to exceed 44 kg / hinge

    The standard glazing system provides a flush attack face and steel beading with fixings on the “non-attack” face. The system is adaptable to various thicknesses of security glazing according to requirements.

     

    Standard Vision Panel Cross Sections

    Steel Bead

     

  •    RatingStandardDescription
    Burglar ResistanceLevel 4AS3555-198810 minute attack with a range of hand tools and power tools
    Fire ResistanceFRR -/120/-AS1530.4 
    Bullet ResistanceG2AS/NZS 2343.44 Magnum
    S0AS/NZS 2343Shotgun 12 gauge, 32 SG Shot

    Test results apply to a single door only, with the specification and hardware described.

    A version of the Armashield-FR is available tested to R2 rating.

     

    Security Testing

    A hinged Armashield-FR door set with Surelock McGill D4 three point locking was subjected to a Level 4 attack according to AS3555-1988 "Building Elements - Testing and Rating for Intruder Resistance".

    Two men attacked the door set with common hand & power tools and succeeded in removing the door leaf from its frame (thus forming an opening in the door set) after 27 minutes 30 seconds.

     

    Ballistic Testing

    The standard Armashield-FR door set has been successfully tested to AS/NZS 2343:1997 “Bullet resistant panels and elements” with ratings of:

    • G2 .44 Magnum
    • S0 Shotgun 12 gauge 32g SG shot

    A version of the Armashield-FR is available tested to R2 rating.

    Ballistic rated door sets require either a fully-grouted frame installation to masonry or concrete walls, or else ballistic protection built into the frame during manufacture. Matching Ballistic Wall Panels are described in a separate section.

     

    Thermal Insulation

    This door leaf has a thermal insulation rating (R-value) of 0.029 Km2/W.

  • The fire-rated Armashield-FR door set may be fitted with a range of security hardware:

    -        locksets with steel or brass latching components for FRR -/60/-
    -        locksets with only steel latching components for FRR -/120/-
    -        any closers, pull handles and minor items of hardware provided they are non-combustible and fixed with steel fasteners.

    Note that fitting of deadlocks and other non-self-latching hardware will make the door set non-compliant in respect to the standard NZS 4520 Fire-resistant door sets.

Product Optional Extras

  • Push or Kickplates

    Kickplates are not generally required on this door set.

    Ventilation Grilles

    Ventilation grilles are not applicable for this door set.