The Pacific Armashield-FR door set is an all-steel security door set, hung in a steel frame. The door set is designed for resistance to attack to the outside (hinge) face. Test results refer to a single leaf hinged door set.
For other door sets fully tested for burglar resistance, fire resistance, bullet resistance and explosion resistance, refer to the Pacific Protector Series.
Product features:
The thickness of the Armashield-FR door leaf is 48mm with an approximate leaf weight of 80kg/m2
Wall Type | Fire Resistance Rating (FRR) | Door Application | Max Leaf Height (mm) | Max Leaf Width (mm) |
Masonry | -/120/- | Single | 2168 | 1021 |
Masonry | -/90/- | Single | 2700 | 1200 |
Notes:
Installation of the fire-rated Armashield-FR requires a fully grouted steel frame in a masonry or precast concrete wall of the appropriate fire rating.
Leaf Facings
All steel leaf with attack face in 6mm steel. Non attack (inside) face is a removable light gauge steel panel.
Leaf Edges
The Armashield-FR has leaf edges edges as shown below.
Meeting Stile
This door set is not available as a pair.
Timber Frame
This door set is only available in a steel frame.
Steel Frame
The steel frame profiles listed below are available for the Armashield-FR door set.
Standard frames are three-sided only with no sill. Four-sided frames and/or custom sills may be available on request. Timber sills are not available on fire doorsets. For more in depth information on frame profiles and sizes, please see our Installation Instructions.
Glazing Type | Maximum Glazed Area | Max Height (mm) | Max Width (mm) | Steel Glazing Bead | FRR with Vision Panel | ||
---|---|---|---|---|---|---|---|
Per VP | Total | Up to 0.065m2 | Over 0.065m2 | ||||
Firelam (2) | 0.091m2 | 0.091m2 | 700 | 130 | √ | -/120/- | -/120/- |
Pyran S (2) | 1.08m2 | 2.16m2 | 1200 | 900 | √ | -/90/- | -/90/- |
NOVOLAY Secure BR4 NS / 1.5.4 (4) | 0.42m2 | 0.84m2 | 700 | 600 | √ | -/60/- | -/60/- |
Notes:
The standard glazing system provides a flush attack face and steel beading with fixings on the “non-attack” face. The system is adaptable to various thicknesses of security glazing according to requirements.
Standard Vision Panel Cross Sections
Steel Bead
Rating | Standard | Description | |
Burglar Resistance | Level 4 | AS3555-1988 | 10 minute attack with a range of hand tools and power tools |
Fire Resistance | FRR -/120/- | AS1530.4 | |
Bullet Resistance | G2 | AS/NZS 2343 | .44 Magnum |
S0 | AS/NZS 2343 | Shotgun 12 gauge, 32 SG Shot |
Test results apply to a single door only, with the specification and hardware described.
A version of the Armashield-FR is available tested to R2 rating.
A hinged Armashield-FR door set with Surelock McGill D4 three point locking was subjected to a Level 4 attack according to AS3555-1988 "Building Elements - Testing and Rating for Intruder Resistance".
Two men attacked the door set with common hand & power tools and succeeded in removing the door leaf from its frame (thus forming an opening in the door set) after 27 minutes 30 seconds.
The standard Armashield-FR door set has been successfully tested to AS/NZS 2343:1997 “Bullet resistant panels and elements” with ratings of:
A version of the Armashield-FR is available tested to R2 rating.
Ballistic rated door sets require either a fully-grouted frame installation to masonry or concrete walls, or else ballistic protection built into the frame during manufacture. Matching Ballistic Wall Panels are described in a separate section.
This door leaf has a thermal insulation rating (R-value) of 0.029 Km2/W.
The fire-rated Armashield-FR door set may be fitted with a range of security hardware:
- locksets with steel or brass latching components for FRR -/60/-
- locksets with only steel latching components for FRR -/120/-
- any closers, pull handles and minor items of hardware provided they are non-combustible and fixed with steel fasteners.
Note that fitting of deadlocks and other non-self-latching hardware will make the door set non-compliant in respect to the standard NZS 4520 Fire-resistant door sets.
Kickplates are not generally required on this door set.
Ventilation grilles are not applicable for this door set.