The AD400 is a hinged flush panel door that is suitable for interior use, available as a single door or as a pair of doors, acoustic tested and designed to reduce sound transmission within buildings.
Product features:
The thickness of the AD400 door leaf is 47mm with an approximate leaf weight of 35kg/m2
Wall Type | Acoustic Rating | Door Application | Max Leaf Height (mm) | Max Leaf Width (mm) |
Steel Stud Wall Timber Stud Wall Masonry Wall | STC/Rw 43 | Single | 2700 | 1200 |
Pair | 2700 | 1200 |
Notes:
Door sets must be installed carefully with particular attention to the sealing of gaps, including around the frame to wall junction.
The facings listed below are available for the AD400 door set
Notes:
Paint-quality doors have unclashed edges.
Timber veneer faced doors are clashed on the vertical edges with solid timber.
Doors faced with decorative laminate or vinyl (e.g. Hospital doors) are capped on the vertical edges with an aluminium extrusion capping with natural anodised finish.
The meeting stiles listed below are applicable to pair door sets only.
The AD400 requires suitable latching in order for the frame seals to fully seal the gap between door leaf and frame.
Practically any standard door hardware can be used on the AD400, however the proposed hardware must be advised to Pacific Door Systems Ltd to assess the suitability, before manufacture.
Any penetrations through the leaf should be packed with acoustic materials (e.g. batts) wherever possible.
Concealed hinges are not an option on this doorset.
Recommended latching points are shown in the below diagram. Pair doorsets require a designated inactive leaf which is secured top and bottom.
The perimeter frame seals are self-adhesive seals mounted in the frame rebate, so are hidden when the door is closed.
There are two options for the bottom seals:
Threshold Seal (Type T) | Compression Seal (Type B) |
An aluminium threshold (natural anodised finish) with integral seal is fitted to the floor. In this case there is no seal required in the bottom edge of the door leaf. The height of the gap between the finished floor level and the bottom of the door must be set up carefully during installation of the door set so that the door will engage with the threshold seal as intended.
| A neoprene seal on the bottom edge of the door leaf engages with a stainless steel threshold plate fitted to the floor.
|
The timber frame profiles listed below are available for the AD400 door set
The steel frame profiles listed below are available for the AD400 door set
Steel frames require packing of the frame during installation with fibrous insulation material (e.g. fibreglass, mineral wool or polyester batts).
For more in depth information on frame profiles and sizes, please see our Installation Instructions.
The AD400 can be supplied with a vision panel of maximum height 1000mm.
Glazing Type | Maximum Glazed Area | Max Height (mm) | Max Width (mm) | Glazing Bead | STC/Rw Rating | |
Timber | Aluminum | |||||
Soundstop | 0.16m2 | 1000 | 860 | √ | √ | 43 |
Soundstop | 0.45m2 | 1000 | 860 | √ | √ | 38
|
Notes:
Size allowance | Standard Cross Section |
Timber Bead | Aluminium Bead |
Smoke control
AD-series acoustic doors are available with a smoke control rating (-/-/-/ SM). These doors comply with the NZBC C/AS2 C6.1.2 definition of smoke control doors.
Thermal insulation
This door leaf has a thermal insulation rating (R-value) of 0.739 Km2/W.
Kickplates of any kind can be surface mounted to this door set.
Overpanels are not an option on this door set as it would impact the acoustic performance of the door set.
Timber framed AD-series acoustic doors can be combined with our SPA-series acoustic windows to form a doorset and sidelight combination. Door and window supplied in separate frames to be joined on site by the installer. Separate acoustic tags will be issued. Overall acoustic performance limited to that of the lowest rated unit.