Pacific PFW60 Fuego-Light Steel Fire Window -/60/30
The Pacific Forster FuegoLight -/60/30 is a fixed glazing, steel framed fire rated window. It provides 60 minutes of integrity and 30 minutes of insulation.
The thickness of the window frame is 65 mm with an approximate glazed weight of 64 kg/m2
Glazing Type | Maximum Glazed Area | Max Height (mm) | Max Width (mm) | Frame Type | Fire Rating | |
Timber | Steel | |||||
Pyrobel 17N | 3.68 m2 | 2676 | 1376 | √ | -/60/30 |
Notes:
- Sizes noted above are the clear view.
- All glazing is Grade A safety glass
Single Pane
Multi Pane
Option 1:
Option 2:
Product Options
Sizing Rules
The maximum allowed clear view is 2676 mm High x 1376 mm Wide. Multiple panes may be joined by transoms/mullions. Maximum allowed total unit height is 4479 mm for interior windows and 4213 mm for exterior windows.
ACoustic Performance
A certified acoustic rating of STC 39 for interior windows and STC 40 for exterior windows is available for this window type. Please notify PDS if you require acoustic certification for your fire window.
Finish
Standard preparation for interior use is powder coating.
Standard preparation for exterior use is sandblasting followed by zinc arc spray (15 year weatherability grade) to frame.
Unit can be delivered with a powder coat finish or primed ready to paint.
Exterior Situations
The window is tested to AS/NZS 4284:2008 – “Testing of building facades” and complies with requirements of NZS 4211:2008 – “Specification for performance of windows” up to and including the Extra High Wind Zone.
Frame Types & Profiles
Steel Frame
The frame is made from 1.5 mm cold formed steel box sections.
For more in depth information on frame profiles and sizes, please see our Installation Instructions.
Wall Types
The Pacific Steel Fire Window -/60/30 is suitable for installation in timber or steel stud plasterboard walls and masonry fire rated walls. Walls to be fire rated to minimum -/60/30 by others.
The standard installation method for steel or timber stud walls is by 12g screws at max. 450 mm centres.
The standard for Masonry installation is M8 Excalibur screwbolts (or similar) at max. 450 mm centres. No fasteners are exposed to weather or attack face.
Acoustical Performance Graphs
Acoustical Performance Graphs
Interior PFW60 windows:
Exterior PFW60 windows:
Thermal Insulation
The glazing used in this window has a thermal insulation rating (R-value) of:
Pyrobel: 0.185 Km2/W
Changes to the NZBC H1 “Energy efficiency” will come into effect gradually starting from November 2022, featuring more stringent requirements for the thermal insulation values of all exterior glazed windows and doors. As a result, some of our products may not be suitable for all climate zones or building types. Customers should take care to specify a suitable product for each specific project and Pacific Doors take no responsibility for incorrect products being selected. Thermal insulation R-values for all our exterior glazing products are listed on the Pacific Doors website.