Pacific AD500 Acoustic Door Set STC/RW 50 Installation

 

This tool is designed to filter the available results as you search. Once you have applied a filter, you may need to reset the filter to be able to see all other available options.

 

Please note:  Hardware is not included with our doors. However, we are pleased to help in sourcing high-quality hardware from ASSA ABLOY at an additional cost.

For BPIR Documents related to ASSA ABLOY hardware, please see: ASSA ABLOY 

For hardware from other suppliers, please refer to the individual hardware supplier for information.

 

To see our installation videos please click here.

Installation wall framing requirements

Pacific AD500 Acoustic Door Set STC/RW 50

WALL TYPE: Timber stud
FRAME TYPE: Timber

Frame materials available:

  • Radiata Pine
  • Hardwood timber

Fasteners:

  • Frame to be screw fixed at 400mm centres nominal. Two fixings per location (10g x 75mm and 14g x 125mm)
  • Architraves optional

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-T-T4 image
WALL TYPE: Timber stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 2.0mm
  • Cold-rolled galvanised - 2.0mm

Fasteners:

  • Frame to be screw fixed at 400mm centres nominal. Two fixings per location (10g x 75mm and 14g x 125mm)
  • Architraves optional

Head Fixing (minimum):

  • Single door - none required
  • Paired door - double central fastener required

Stud size:

  • Stud to suit acoustic wall system of equal or greater rating required

Wedging gap:

  • 0-10mm
A-D-AD-S-T5 image